{"action":"Upgrade org.jenkins-ci.plugins:aqua-microscanner to 1.0.8 or later.","affected":[{"fixed":"1.0.8","introduced":"0"}],"component":"org.jenkins-ci.plugins:aqua-microscanner","cve_ids":["CVE-2019-10427"],"ecosystem":"Maven","epss":0.00771,"exploited":false,"fixed_versions":["1.0.8"],"ghsa_id":"GHSA-vv4q-2w98-4v8g","id":"tcs_01M5N9ET06EHE6WYRDJRHRBR2G","modified_at":"2024-02-16T08:12:35.292306Z","published_at":"2022-05-24T22:00:44Z","references":["https://osv.dev/vulnerability/GHSA-vv4q-2w98-4v8g","https://nvd.nist.gov/vuln/detail/CVE-2019-10427","https://jenkins.io/security/advisory/2019-09-25/#SECURITY-1507","http://www.openwall.com/lists/oss-security/2019/09/25/3"],"severity":{"label":"medium","score":5.3},"sources":[{"source":"osv","source_id":"GHSA-vv4q-2w98-4v8g","url":"https://osv.dev/vulnerability/GHSA-vv4q-2w98-4v8g"}],"summary":"Jenkins Aqua MicroScanner Plugin showed plain text credential in configuration form"}